Please use this identifier to cite or link to this item: http://repository.aaup.edu/jspui/handle/123456789/1725
Title: The effect of recurrent application of concentrated platelet-rich fibrin inside the extraction socket on the hard and soft tissues: a randomized controlled trial
Authors: Abu-Ta'a, Mahmoud$AAUP$Palestinian
Lahham, Cezar$AAUP$Palestinian
Lahham, Elias$Other$Palestinian
Saleem, Michael$Other$Palestinian
Zarif, Wael$Other$Other
Keywords: Recurrent injections
PRF
ridge alterations
tooth extraction
ridge preservation
Issue Date: 19-Sep-2023
Publisher: Springer Nature
Citation: BMC Oral Health
Abstract: Background: Platelet-rich fibrin (PRF) is commonly used for ridge preservation following tooth extraction. However, its effectiveness diminishes over a period of two weeks as it is resorbed and loses its biological activities. Therefore, this clinical study aims to evaluate the effect of recurrent application of concentrated PRF (C-PRF) inside the extraction socket on the hard and soft tissue alterations. Methods: Twenty patients requiring single tooth extraction and replacement with a dental implant were randomized into one of two ridge preservation approaches: Advanced PRF plus alone (Control group) or advanced PRF plus with the recurrent application of a C-PRF inside the socket every two weeks for 2 months (four times). The ridge width, the ridge height, and the soft tissue thickness were assessed clinically at the baseline and reassessed after 3 months from tooth extraction during implant surgery. Then the amount of hard tissue loss and soft tissue alterations were calculated. Results: There was a statistically significant difference in the amount of hard tissue loss between groups in the third month. The amount of horizontal ridge loss for the control and test groups were 2.9±0.7 mm and 1.9±0.5 mm, respectively (p-value<0.05). The vertical bone loss for control and test groups were 1.8±0.5 mm and 1.0±0.3 mm, respectively (p-value<0.05). Additionally, for the soft tissue thickness, there was no statistical difference between the groups (p-value>0.05). Conclusion: Within the limitations of this study, the recurrent application of C-PRF in the extraction socket could decrease the amount of ridge alteration following tooth extraction and may play a role in the bone regeneration procedures. Trial registration Registered on ClinicalTrials.gov (ID: NCT05492357, on 08/08/2022).
URI: http://repository.aaup.edu/jspui/handle/123456789/1725
ISSN: doi.org/10.1186/s12903-023-03400-5
Appears in Collections:Faculty & Staff Scientific Research publications

Files in This Item:
File Description SizeFormat 
PRF liquid inside extractio socket BMC Oral health 2023.pdf1.31 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Admin Tools